Rins136 Issue 9 Page 23
9.4 Setting the Panel when Mains Fails
Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to
Set and Unset the control panel during a mains fail if allowed in System Option 2 and no further action is required.
Full functionality of the control panel is available during mains fail.
9.5 Programming Set Modes.
Any zone may be programmed to be any one of the following:
Entry / Exit = E Access = A Tamper = T Immediate = I Omitted = O
24 Hour = H Fire = F Momentary Keyswitch = Y Latch Keyswitch =
The attribute for each zone is selected by pressing
or until the required symbol appears in the display.
When the required symbol appears pressing the key will select the attribute, a two tone acceptance will be heard
and the next zone will automatically be selected.
NOTE: On pressing
after selecting the attribute for zone 8, the programme for the required SET will be stored
automatically.
To programme SET A enter
Then select attribute for each zone.
To programme SET B enter Then select attribute for each zone.
To programme SET C enter Then select attribute for each zone.
To programme SET D enter Then select attribute for each zone.
Should you wish to view any zone status within a Set mode use the same procedure,
but do not scroll the
keys. Enter to select the attribute for the zone. After selecting the attribute for zone
8, the progamme for the required SET will be stored automatically and the program will be exited.
9.6 Setting the Alarm Bell Time
To adjust the alarm bell cut off time. Enter
followed by the required time in minutes (
to minutes) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The alarm bell cut off time for the Sterling 10 is factory set to 20 minutes.
9.7 Setting Entry Time
To set the required Entry time. Enter
followed by the time required in seconds ( to seconds) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Entry time is factory set to 30 seconds.
9.8 Setting Exit Time
To set the required Exit time Enter
followed by the time required in seconds (
to seconds) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Exit time is factory set to 30 seconds.
9.9 Setting Bell Delay
To set the required Bell Delay. Enter
followed by the time required in minutes(
to minutes) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps. Bell Delay is factory set to
zero minutes.
9.10 Setting Communication Delay
To set the required Communication Delay Enter
followed by the time required in seconds (
to seconds) followed by .