104
ESP-LXIVM Series Controllers
Power Down or Restore Power to the 2-Wire path
Turn the controller dial to OFF
At the All Watering Off screen, press the 2-Wire path key.
The 2-Wire path On/Off screen will appear. Normally the 2-Wire
path will be ON, unless you have previously turned it off. Press
the Off key.
All Watering Off
9:43 AMOFF
Contrast 10 MV 2wire
2-wire Path on/off
OnPath
2-wire
At the confirmation screen, press and HOLD the Yes key for 4 sec-
onds to turn off the 2-Wire path. If you’re not sure, press No.
A confirmation screen shows status of the 2-Wire path.
WARNING!
Irrigation functions
will be disabled
Press and hold Yes
to proceed
2-Wire Path Off
are disabled
Irrigation functions
Repeat this process and press the On key to restore power to
the 2-Wire path.
NOTE: It’s not necessary to leave the controller dial in the OFF
position when the 2-Wire path is off. You can still change Pro-
grams or perform other tasks. But while the 2-Wire path is pow-
ered down, the controller’s alarm light will be lit and a 2-Wire
path Off message will be shown whenever the controller dial is
at the OFF or AUTO dial positions.