76
ESP-LXIVM Series Controllers
At the LEARN FLOW MENU screen, with All Stations selected,
press Next.
A confirmation screen appears; press Next again.
LEARN FLOW MENU
Selection Stations
All Stations
for stations with...
only
Learn Flow will work
An information screen appears; press Next again.
To start the Learn Flow exercise immediately, press Next. Or else
press the + and – keys to set a delayed start time. Press the Arrow
keys to navigate between the number setting fields.
NOTE: You can choose to run the exercise Now (00:00) or choose
a timed delay of up to 24 hours.
Learn Flow
Priority
4. Assigned MV
3. High/Medium/Low
2. Station Runtime
1. Station Address
Learn Flow
00 : 00
HH:MM
Start Learn Flow In
A confirmation screen appears, confirming the Learn Flow will
overwrite the existing flow rates. Press Start to set the Learn Flow
exercise.
The Learn Flow Starting confirmation screen shows the time
delay until the Learn Flow operation will start.
existing learned
overwrite
Learn Flow will
Attention
flow rates
Starting Now
Learn Flow
NOTE: An alarm will be posted if one or more stations learn a
flow rate of 0 (zero). Check the valve and 2-Wire Device if you
receive this alarm.
NOTICE
Be sure to Learn Flow again if you make any changes to your
system which affect its hydraulics.
Selected Stations
NOTE: Ensure you have Run Times set up for all stations included
in a Learn Flow exercise prior to setting up a Learn Flow.
Turn the controller dial to Flow Sensor
At the FLOW SENSOR screen, with Set Flow Rates selected, press
Next.
At the Set Flow Rates screen, with Learn Flow selected, press Next
FLOW SENSOR
Current Flow Reading
Set Flow Units
Set FloWatch
Set FloManager
Set Flow Rates
Set Flow Rates
View Flow Rates
Clear Flow Rates
Set FloZone Rates
Set Station Rates
Learn Flow