P/N 016-4010-001 Rev. A 43
STEERING SETUP
WHEEL ANGLE SENSOR SETTINGS
FIGURE 9. Wheel Angle Sensor Calibration Screen
Left/Center/Right - Displays the current calibration values. These values can be modified by selecting the
desired WAS value to be changed, moving the wheels to the correct position, and pressing the Accept button.
Current Sensor Voltage - Displays the sensor voltage detected during calibration.