1 INTRODUCTION
1.2 Voltage and Temperature Performance
Voltage (V)
1 Sec
1 Sec
Continuous
1 Min
10.5 V
0%
100%
115%
(3000 W) 200%
16 V 16.5 V
Power (W)
175%
(1000 W
1500 W
2000 W)
FIGURE 1.2.1: Output Power vs. Input Voltage (1000–3000W)
Temperature ºF (ºC)
1 Sec
Continuous
Output Power
1 Min
−4°F
(−20 °C)
0%
100%
115%
(3000 W) 200%
40%
32 °F
(0 °C)
104 °F
(40°C)
140°F
(60°C)
Power (W)
175%
(1000 W
1500 W
2000 W)
FIGURE 1.2.2: Output Power vs. Input Air Temperature (1000–3000W)