The AC Fault alarm is deliberately slow, when the AC is removed or applied, the Rhino Panic
Pack will take some time before the fault is generated or cleared.
Battery Test Period
This timer is used to control frequency (0-255 hours) at which the standby battery is load tested.
Default = 24 hours.
Bell Duration
When an alarm is generated, this timer is used to control the active duration of the siren.
Hardware Monitoring
This set of options allows the monitoring of the Rhino Panic Pack hardware to be enabled or
disabled.
Panel Box Tamper
1
The box tamper is monitored for activity (default)
On:
The box tamper is not monitored
Off:
Reserved
2
System Voltage
3
On:
The system voltage is not monitored
Off:
The system voltage is monitored for faults (default)
Battery Presence
4
On:
The standby battery is not monitored
Off:
The standby battery is monitored for its presence (default)
Mains AC
5
On:
The mains supply is not monitored
Off:
The mains supply is monitored for its presence (default)
Configuration 1
This set of options allows the system operation and features to be altered.
Enable Panic Pack Operation
1
Rhino Panic Pack operation is normal
On:
The Rhino Panic Pack operation is disabled. All Rhino Panic Pack functions including alarm
Off:
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Configuration Programming Page
To program the system timers, hardware and general configuration option, click on the
“Configuration” icon in the “Programming” section on the left hand navigation bar:
17
transmissions to the ARC, will be stopped. The 7-segment display will show --.