6.1.12. Misaligned Output (Data shifted to the right or left)
Possible Cause (Scanner)
• Incorrect setting of the document guide.
Action:
• Align the document guides to each side of the document.
Possible Cause (Printer)
• Incorrect setting of the printing paper.
Action:
• Re-install the paper roll.
6.2. MECHANICAL PROBLEMS
6.2.1. ADF/Scanner
1. Non Feed
Possible Cause:
• An incorrect type or size of document is used.
• The operation panel is not properly closed.
• The ADF and feed rollers are dirty or worn out.
• Incorrect positioning of the separation pad, or the pad is missing.
• The Tx motor is defective.
Action:
1. Check that a correct type of document is being used.
2. Check that the operation panel is securely closed.
3. If the problem still remains, do the following.
• Clean the ADF and feed rollers with a soft cloth and water, and replace
them if they are damaged.
• Check the spring of the separation pad and replace it if it is damaged.
• Check the connection between the FCU (CN4) and the Tx motor.
• Replace the Tx motor.
TROUBLESHOOTING August 7th, 1995
MECHANICAL PROBLEMS