EasyManuals Logo
Home>Rotax>Engine>503 UL DCDI

Rotax 503 UL DCDI User Manual

Rotax 503 UL DCDI
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
d04094
page 10 - 14
Jan. 01/2007
Effectivity: 447 SCDI, 503 DCDI,
582 DCDI
OM Edition 1 / Rev. 0
BRP-Rotax
10.3.4) Engine start
WARNING! Do not take the engine into operation if any person
is near the aircraft.
On cold engine, apply choke fully. Ensure idle position of throttle
valves as opening throttle will greatly reduce choke effect resulting
in hard starting.
Make sure ignition switch is on and that you can shut it off instantly
if necessary. Pull starter until firmly engaged and then pull smartly
through.
CAUTION: At employment of an electric starter, activate
starter for max. 10 sec. only (without interuption),
followed by a cooling period of 2 min.
Above procedure should be repeated until engine begins to "fire".
As soon as engine starts, shift the throttle slowly to low speed and
remove choke as soon as possible. Prolonged use of choke can
cause engine to flood.
If the engine fails to start or operates only on one cylinder, check
whether the ignition wiring is correctly connected to the spark plug
connectors, check spark plugs and check the ignition is in ON
position.
CAUTION: Ensure grounding switch is in correct position and
wired correctly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 503 UL DCDI and is the answer not in the manual?

Rotax 503 UL DCDI Specifications

General IconGeneral
BrandRotax
Model503 UL DCDI
CategoryEngine
LanguageEnglish

Related product manuals