244
Bit0
0: stop status
1: run status
Read VFD fault
code
E000H(1E00H)
Address E000H and 1E00H interchangeablerefer to fault code table and
example of read function code 03H
Read VFD fault
pre-alarm
code
E001H(1E01H)
Address E001H and 1E01H interchangeablerefer to example of pre-alarm
code, read function code 03H
User password
check
AD00H(1C00H)
Address AD00H and 1C00H interchangeablerefer to example of write
function code 06H
Operation
limit password
check
AD01H(1C01H)
Address AD00H and 1C00H interchangeablerefer to example of write
function code 06H
5.4 Fault Code
Fault code
Displayed code
Fault information
0000H
——
No fault
0001H
E-01
Overcurrent when accelerating
0002H
E-02
Overcurrent when decelerating
0003H
E-03
Overcurrent at constant speed
0004H
E-04
Overvoltage when accelerating
0005H
E-05
Overvoltage when decelerating
0006H
E-06
Overvoltage at constant speed