3 Installation and Commissioning
Frei verwendbar House Control with Master-Slave - LOGO! Set 9
Entry ID: 64143308, V2.2, 09/2018
27
© Siemens AG
2018 All rights reserved
3.7 Adjust the runtime of the blinds in the LOGO! program
In the LOGO! program a blind runtime of 40 seconds until the end stop is defined.
Check the exact runtime until end stop of the blinds you use. If the runtime is a
different value than 40 seconds we recommend the settings of following
parameters for an optimized control of the blinds and for display:
Table 3-5
No.
Action/response
KTP700 display
1.
1. Unzip and execute the
LOGO! Soft Comfort V8 project
from the download.
2. Open the master program by double-
clicking it.
2.
1. Move blinds up (see Table 4-2)
2. Note down the runtime.
3.
1. Navigate in the program to the function
blocks B006, B013, B010, and B030.
2. With a double click on the respective block
the block properties are being opened.
3. Set in the block properties of this function
blocks the values as noted down in item 2.
4.
Activate the online test by clicking "Online test”
and follow the menu navigation.
5.
1. Go to function block B023/B068 in the
master program.
2. Click the icon with the pair of glasses to
monitor the value.
3. Note down the displayed value (see marker
frame).
4. Deactivate the online test.