EasyManuals Logo
Home>Siemens>Switch>SCALANCE XC-100

Siemens SCALANCE XC-100 User Manual

Siemens SCALANCE XC-100
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
SCALANCE XC-100
Operating Instructions, 06/2016, C79000-G8976-C415-02
29
Connecting up
5
5.1
Safety when connecting up
Safety notices
When connecting up the device, keep to the safety notices listed below.
WARNING
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1
must be connected to the power supply terminals. The power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code
(r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
NOTICE
Failure of the data traffic due to contamination of optical plug-in connections
Optical sockets and plugs are sensitive to contamination of the end face. Contamination
can lead to the failure of the optical transmission network.
Close unused optical sockets and plugs as well as pluggable transceivers and slots with the
supplied protective caps.
Remove the protective caps only immediately before you use the plug-in connection.
Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
Do not connect or disconnect cables to or from the device when a flammable or
combustible atmosphere is present.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-100 and is the answer not in the manual?

Siemens SCALANCE XC-100 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-100
CategorySwitch
LanguageEnglish

Related product manuals