12.96 Technical Data
Siemens AG 6SE7087-6BM70
9-1
SIMOVERT MASTER DRIVES Operating Instructions
9 Technical Data
The drive converters correspond to the listed conditions as well as the specified domestic and international
standards.
Switching at the input
No./min 2
Cooling medium temperature
0 °C to +40 °C
Storage temperature
−
25 °C to +70 °C
Transport temperature
−
25 °C to +70 °C
Environmental class
3K3 DIN IEC 721-3-3
Moisture condensation not permissible
Pollution level
2 DIN VDE 0110 Pert 1
Overvoltage category
III DIN VDE 0110 Part 2
Overvoltage property class
1 E DIN VDE 0160
Protection class
I DIN VDE 0106 Section 1
Radio interference level
−
standard
without
DIN VDE 0875 Section 11 =^ EN 55011
Noise immunity
EN50082-2
Mechanical strength
DIN IEC 68-2-6 / 06.90
Frequency range Constant amplitude of the
deflection acceleration
Hz mm m/s
2
(g)
−
when stationary (in op.)
10 to 58
above 58 to 500
0.075
9.8 (1)
−
during transport
5 to 9
above 9 to 500
3.5
9.8 (1)