Technical Data 12.96
9-6 Siemens AG 6SE7087-6BM70
SIMOVERT MASTER DRIVES Operating Instructions
Inverter types 6SE70... 41-0WM20 41-1WM20 41-2WM20 41-4WM20 41-6WM20
Rated voltage, rated frequency, rated current, rated output
Rated voltage in V
n
Input
Output
V
DC 890...930 ±15 %
3 AC 0 ... Rated voltage / 1.35
Rated frequency f
n
Input
Output: U/f = konst
U = konst
Hz
0 ... 600
8 ... 300
Rated current I
n
Input
Output
A
1178
990
1285
1080
1464
1230
1666
1400
1880
1580
DC link voltage V
dn
V = Rated voltage
Rated output kVA 1132..1183 1235..1291 1406..1470 1600..1673 1806..1888
Auxiliary power supply
DC 24 V (20 V - 30 V)
A 5 + 3 without Options;
with Options refer to Section 6.1
Auxiliary power supply V AC 230
±
15%
Loading Class II acc. to EN 60146-1-1
Rated current A 901 983 1119 1274 1438
Base load time s 240
Overcurrent A 1346 1469 1673 1904 2149
Overcurrent time s 60
Losses, cooling, power factor
Power factor
Converter cos
ϕ
U
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
Efficiency
η
−
Pulse frequency 2.5 kHz 0.98 0.98 0.98 0.98 0.98
Power loss
−
Pulse frequency 2.5 kHz
kW
16 20 23.9 29 33.3
Required cooling air flow m
3
/s 1.5 1.5 1.5 1.7 1.7
Pressure drop
∆
p Pa 640 640 640 950 950
Sound pressure level, dimensions, weights
Sound pressure level dB(A) 85 85 85 88 88
Type MMMMM
Width
Height
Depth
mm 2300
1910
580
2300
1910
580
2300
1910
580
2300
1910
580
2300
1910
580
Ground
− IP00
kg
ca. 1500 ca. 1500 ca. 1500 ca. 1500 ca. 1500
Required current for fan (typical)
230 V / 50 Hz A 10.4 10.4 10.4 26.8 26.8
230 V / 60 Hz A 13.4 13.4 13.4 40.0 40.0