05.2006 Control Word and Status Word
Siemens AG 6SE7087-2JD60
SIMOVERT MASTERDRIVES Operating Instructions 10-17
1=Ready for operation (DC link loaded, pulses disabled)
0=Not ready for operation
Function diagram
87654321
Status word 1
MASTERDRIVES VC
- 200 -
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
1=Ready to switch on
0=Not ready to switch on
Meaning
1=Run (voltage at output terminals)
0=Pulses disabled
1=Fault active (pulses disabled)
0=No fault
0=OFF2 active
1=No OFF2
0=OFF3 active
1=No OFF3
1=Switch-on inhibit
0=No switch-on inhibit (possible to switch on)
1=Warning active
0=No warning
1=No setpoint/actual value deviation detected
0=Setpoint/actual value deviation
1=PZD control requested (always 1)
1=Comparison value reached
0=Comparison value not reached
1=Low voltage fault
0=No low voltge fault
1=Request to energize main contactor
0=No request to energize main contactor
1=Ramp-function generator active
0=Ramp-function generator not active
1=Kinetic buffering/flexible response active
0=Kinetic buffering/flexible response inactive
1=Positive speed setpoint
0=Negative speed setpoint
Status word 1
r552
K0032
Status word 1
Bit No.
Bit 0
Display of r552 on the PMU
1415 13 12 11 10 9
8
01234567
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from alarm processing
from messages [480.7]
from messages [480.7]
from fault processing
from setpoint processing
[317.8], [327.8]
from messages [480.7]
From KIB/FLR control
[600.8], [605.8]
B0100
Rdy for ON
1
B0101 Not Rdy for ON
B0102
Rdy for Oper
1
B0103 NotRdy for Oper
B0104
Operation
1
B0105 Not operating
B0106
Fault
1
B0107 No fault
B0108
No OFF2
1
B0109 OFF2
B0110
No OFF3
1
B0111 OFF3
B0112
Blocked
1
B0113 Not blocked
B0114
Alarm
1
B0115 No alarm
B0116
No Deviation
1
B0117 Deviation
B0120
CompV OK
1
B0121 CompV not OK
B0122
Low Voltage
1
B0123 No Low Voltage
B0124
Energize MCon
1
B0125 N.Energ.MCon
B0126
RampGen active
1
B0127 RampGen n.act.
B0128
Speed Setp FWD
1
B0129 Speed Setp REV
B0130
KIB/FLR active
1
B0131 KIB/FLR n.active
The sequence control is the internal
control (software) for realizing the
drive status (r001).
1)
n959.27 = 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Vector Control and is the answer not in the manual?

Siemens Vector Control Specifications

General IconGeneral
BrandSiemens
ModelVector Control
CategoryMedia Converter
LanguageEnglish

Related product manuals