Control Word and Status Word 05.2006
6SE7087-2JD60 Siemens AG
10-18 Operating Instructions SIMOVERT MASTERDRIVES
1=Synchronism achieved
0=Synchronism not achieved
Function diagram
87654321
Status word 2
MASTERDRIVES VC
- 210 -
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31
1=Flying restart or excitation active
0=Flying restart not active or excitation finished
Meaning
0=Overspeed
1=No overspeed
1=External fault 1 active
0=No external fault 1
1=External fault 2 active
0=No external fault 2
1=External warning active
0=No external warning
1=Converter overload warning active
0=No converter overload warning
1=Converter overtemperature fault active
0=No converter overtemperature fault
1=Converter overtemperature warning active
0=No converter overtemperature warning
1=Motor overtemperature warning active
0=No motor overtemperature warning
1=Motor overtemperature fault active
O=No motor overtemperature fault
Reserve
1=Motor pulled out/blocked fault active
0=No motor pulled out/blocked fault
1=Bypass contactor energized (only AC units)
0=Bypass contactor not energized
1=Pre-charging active
0=Pre-charging not active
1=Fault during synchronization
0=No fault during synchronization
Status word 2
r553
K0033
Status word 2
Bit No.
Bit 16
Display of r553 on the PMU
3031 29 28 27 26 25
24
1617181920212223
from sequence control 1)
from synchronization [X01.6]
from messages [480.7]
from sequence control 1)
from sequence control 1)
from sequence control 1)
from alarm processing
from block/pullout
diagnosis [485.8]
from fault processing
from alarm processing
from alarm processing
from fault processing
from sequence control 1)
from synchronization [X01.6]
from sequence control 1)
B0132
Fly/Exc active
1
B0133 Fly/Exc n.act.
B0134
Sync reached
1
B0135 Sync n.reached
B0136
Overspeed
1
B0137 No Overspeed
B0138
Ext Fault 1
1
B0139 No Ext Fault 1
B0140
Ext Fault 2
1
B0141 No Ext Fault 2
B0142
Ext Warning
1
B0143 No Ext Warning
B0144
Ovld Warn Drive
1
B0145 No OvldWarn Drv
B0146
Tmp Flt Drive
1
B0147 No Tmp Flt Drv
B0148
TmpWarn Drive
1
B0149 No TmpWarn Drv
B0150
TmpWarnMotor
1
B0151 No TmpWarnMotor
B0152
TmpFltMotor
1
B0153 No TmpFltMotor
B0156
Motor PullOut
1
B0157 No MotorPullOut
B0158
ChrgRelay close
1
B0159 ChrgRelay open
B0160
Sync Fault
1
B0161 No Sync Fault
B0162
Prechrg active
1
B0163 Prechrg n.act.
The sequence control is the internal
control (software) for realizing the
drive status (r001).
1)
B0255
ExcitationEnd
in addition
2)
2)
n959.28 = 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Vector Control and is the answer not in the manual?

Siemens Vector Control Specifications

General IconGeneral
BrandSiemens
ModelVector Control
CategoryMedia Converter
LanguageEnglish

Related product manuals