1. Press and release the jog wheel above the left grouphead to
activate the menu for all groupheads.
2. Rotate the jog wheel clockwise until the “Brew
Temperature” setting appears.
3. Press and release the jog wheel to enter the “Brew
Temperature” setting.
4. Rotate the jog wheel to adjust the brew tank temperature in
tenth-degree
(0.1-degree) increments: clockwise rotations increase the
temperature; counter-clockwise rotations decrease the
temperature.
5. Press and release the jog wheel to confirm your new setting
and proceed to the next step; the option to apply your new
setting to all groupheads will be presented.
6. Rotate the jog wheel to cycle between “N” and “Y”. Selecting
“N” will apply your new setting to the designated grouphead
only; selecting “Y” will apply your new setting to all
groupheads.
7. Press and release the jog wheel to confirm your new setting
and return to the menu, and scroll to the next menu option.
To configure a different temperature for each brew tank,
repeat steps 1-7 at each grouphead.
Protip: To quick exit the program menu move the actuator
Left/Right to Save and Exit the menu.
1. Press and release the jog wheel above any grouphead to
activate the menu.
2. Rotate the jog wheel clockwise until the “Steam Tank” setting
appears.
3. Press and release the jog wheel to enter the “Steam Tank”
setting.
4. Rotate the jog wheel to adjust the steam tank pressure in
tenth-bar (0.1-bar) increments: clockwise rotations increase
the temperature; counter-clockwise rotations decrease the
temperature.
5. Press and release the jog wheel to confirm your new setting
and return to the menu, or press and hold the jog wheel to
confirm your new setting and exit the menu.
ADJUST BREW TANK TEMPERATURES
At the factory, the brew tank temperatures are set to 93° C (200° F).
Adjust the brew tank temperatures with the following steps.
PROCEDURE
ADJUST STEAM TANK PRESSURE
At the factory, the steam tank temperature is set to 1.4 bar (25 psi).
Adjust the steam tank temperature with the following steps.
PROCEDURE
28
SLAYER STEAM X USER MANUAL V1.1 | SEPTEMBER 2019

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Slayer Professional Series and is the answer not in the manual?

Slayer Professional Series Specifications

General IconGeneral
BrandSlayer
ModelProfessional Series
CategoryCoffee Maker
LanguageEnglish

Related product manuals