2-2. SERVICE POSITION
VC-352
VC-352
AC power
adaptor
AC IN
1
8
[SERVICE POSITION TO CHECK THE VTR SECTION]
Connection to Check the VTR Section
To check the VTR section, set the VTR to the "Forced VTR power ON" mode.
Operate the VTR functions using the touch panel. (When the control switch block (ZM6800) is removed, the function
buttons of the adjustment remote commander are not effective even if the HOLD switch of the adjustment remote
commander is set to the OFF position.)
Setting the "Forced VTR Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: A, address: 10, set data: 02, and press the
PAUSE button of the adjustment remote commander.
To eject a cassette, connect the
control switch block (SS6800)(18P)
Exiting the "Forced VTR Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: A, address: 10, set data: 00, and press the
PAUSE button of the adjustment remote commander.