Troubleshooting Guides
Built-In
Built-In
(600-
(600-
2
2
)
)
Series
Series
8-16
#3758407 - Revision B - August, 2006
SEALED SYSTEM DIAGNOSTICS TABLES
Before entering sealed system, see General Troubleshooting Guide starting on page 8-5, specifically problems “A” -
“D”, referencing “Pointers” in first column. By initiating Diagnostic Mode and observing evaporator temperatures, you
may find it unnecessary to enter the sealed system. The table on following page also provides a quick reference for
temperature/pressure correlation.
NOTE: Always use solder-on process valves. Do NOT
use bolt-on process valves as they are prone to leak.
NOTE: Whenever servicing the sealed system, the high-side filter-drier must be replaced.
NORMAL OPERATING PRESSURES
Model Normal Low-Side Pressures Normal High-Side Pressures
601R-2
601RG-2
601F-2
611-2
611G-2
632-2
642-2
650-2
650G-2
661-2
685-2
695-2
Refrigerator
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
5-12 psi to 35-42 psi
5-12 psi to 35-42 psi
1-3” vacuum to 8-15 psi
5-12 psi to 35-42 psi
1-3” vacuum to 8-15 psi
5-12 psi to 35-42 psi
1-3” vacuum to 8-15 psi
0-10 psi to 30-38 psi
1-3” vacuum to 6-12 psi
0-10 psi to 30-38 psi
1-3” vacuum to 6-12 psi
5-12 psi to 30-38 psi
1-3” vacuum to 6-12 psi
5-12 psi to 30-38 psi
1-3” vacuum to 6-12 psi
5-12 psi to 35-42 psi
0-3” vacuum to 8-15 psi
5-12 psi to 35-42 psi
0-5” vacuum to 8-15 psi
5-12 psi to 35-42 psi
0-5” vacuum to 8-15 psi
90 psi to 100 psi
90 psi to 100 psi
90 psi to 100 psi
90 psi to 100 psi
90 psi to 100 psi
90 psi to 100 psi
90 psi to 100 psi
110 psi to 130 psi
110 psi to 130 psi
85 psi to 100 psi
75 psi to 90 psi
85 psi to 100 psi
75 psi to 90 psi
85 psi to 100 psi
75 psi to 90 psi
90 psi to 100 psi
75 psi to 90 psi
90 psi to 100 psi
75 psi to 90 psi
90 psi to 100 psi
75 psi to 90 psi