CHANNEL
1 HORIZONTAL ---.J
CHANNEL
2
(REFERENCE
))
DIFFERENCE r (REFERENCE)
I ~.-..'
~-+-~
--~
101--+
-+--
t--t
-
-l::-
-+--4
-
-+
-
+----i
o .
·c
H 1 SIGNAL
..
+---+--+--+--+-"'f-
-~
A FOR CH 1
ALT HORIZ SWEEP
DISPLAY
B FOR
CH2
'VERTICAL
REFERENCE
LINE
4732-13
Figure 4-15.
Time
difference
between
two
pulses
on
two
time-
related signals.
Operating Procedures-2215A Operators
11. Calculate the
ti
me difference between the Channel 1
and Channel 2 pulses as in the preceding ' Time Difference
On Single Waveforms· measurement procedure.
EXAMPLE: With the A SEC/DIV switch set
to
50
µs
per
division, the dial reading for the reference pulse (Channel 1)
is
2.60 and the dial reading for the comparison pulse (Chan-
nel 2)
is
7.10.
Substituting the given values i
nto
the time-difference
formula:
Time Difference = (7.10 - 2.60) (50 µs/di
v)
= 225
µs
4-
13

Table of Contents

Other manuals for Tektronix 2215A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2215A and is the answer not in the manual?

Tektronix 2215A Specifications

General IconGeneral
BrandTektronix
Model2215A
CategoryTest Equipment
LanguageEnglish

Related product manuals