EasyManuals Logo
Home>Tektronix>Multimeter>DMM4020

Tektronix DMM4020 Safety And Installation Instructions

Tektronix DMM4020
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
I
Additional Current Errors
Additional
NPLC
Noise
Error
for
Additional
NPLC
Noise
Error
Digits
NPLC
1 rnA, 100 rnA,
400
rnA, 3 A
and
for
100
IJA.
10
rnA. 1 A
6
Y,
100
10
A
0 %
of
range
0 %
of
range
6
Y,
10
0%
of
range
0 %
of
range
5
Y,
5Y,
4Y,
1
0.2
0.02
0.001 %
of
range
0.011
% of range ±4
IJA
0.04 %
of
range ±4
!JA
0.
01
%
of
range
0.
11
%
of
range ±4
!JA
0.28 % of range
±4
!JA
AC
Current
The following ac current specifications are for sinusoidal signals with amplitudes greater than 5 %
of
range. For inputs
from 1 % to 5 % of range, add an additional error
of
0.1
%
of
range.
Input Protection ... .....
.. ..
.......
..
....
..
.............
..
..
....
....
. Tool accessible
11
Al1000
V and 440 mA/1000 V fuses, limits of
400
mA
continuous 550 mA for 2 minutes
on
, 1 minute off.
Measurement Method .... ....
..
....
..
..
....
....
...
......
..
ac-coupied true-rms, dc-coupled to the fuse and shunt (no blocking
capacitor)
AC Filter Bandwidth
Slow ....
..
...
....
..
..
........... ......
.. ..
...
..
....
..
.
..
3 Hz to 10 kHz
Medium
..
........
..
..
..
..
.
...
.. ....
..........
..
..
.....
..... ....
..
..
20
Hz
to 10 kHz
Fast..
...
.....
.. ....
...
..
..
......
...
.........
..
...
.... 200 Hz to 10 kHz
Crest Factor Error (applies to non-sinusoidal waveforms only)
Maximum Crest Factor
..
..
..
...........
..
...
...
....
.. ..
. 5:1 at full scale
Additional Crest Factor Errors
«100
Hz) ... Crest factor 1-
2,0.05
%
of
full scale
Crest factor 2-3, 0.2 %
of
full scale
Crest factor 3-4, 0.4
%
of
full scale
Crest factor 4-5, 0.5 %
of
full scale
Input Characteristics
I
I
Resolution
Shunt
Resistance
Range
Resolution
4'!.
Digits
5'1,
Digits
6'1,
Digits
(Ohms)
100
!JA
100.0000
!JA
10 nA 1
nA
100
pA
100 n
1
mA
1.000000
mA
100 nA 10 nA 1 nA
100
n
10
mA
10.00000
mA
1!JA
100
nA
10 nA
1
n
100
mA
100.0000
mA
10
!JA
1!JA
100
nA
1 n
400
mA
13
1
400.000 mA
100
!JA
10
!JA
1!JA
1 n
1 A
(21
1.000000 A
100
!JA
10
!JA
1!JA
0.
01
n
3 A
['
112
1
3.00000 A 1 mA
100
!JA
10
!JA
0.
01
n
10 A
[21
10.00000 A 1
mA
100
!JA
10
IJA
0.01 n
111
Part
of
10 A
range
12)
Available
at
front
panel
conne
c
tors
only
Burden
Voltage
<0.015 V
<
0.15V
<0.025 V
<0.25 V
<0.50 V
<0.05 V
<0.05 V
<0.5 V
PJ
400
mA
available
in
softwar
e
version
1.0.700.18
or
grealer o
nly
. 400
mA
continu
o
usly
; 550
mA
for
2
minutes
o
n,
1
minute
off;
maximum
crest
factor
3: 1
at
400
mA
J
27

Table of Contents

Other manuals for Tektronix DMM4020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DMM4020 and is the answer not in the manual?

Tektronix DMM4020 Specifications

General IconGeneral
BrandTektronix
ModelDMM4020
CategoryMultimeter
LanguageEnglish

Related product manuals