EasyManuals Logo
Home>Tektronix>Test Equipment>MDO3000 Series

Tektronix MDO3000 Series Program Manual

Tektronix MDO3000 Series
1158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #998 background imageLoading...
Page #998 background image
Commands Listed in Alphabetical Order
Examples
WFMOutpre:REF
Level?
might return 1.0000E-3, indicating a Reference Level
of 1 mW.
WFMOutpre:SPAN? (Query Only)
This query returns the frequency span of the outgoing waveform. For non-MDO
models, this query always returns 0.0.
The span is the range of frequencies you can observe around the center frequency.
Conditions
MDO3000, MDO4000/B, or MDO4000C models with option SA3 or SA6 only.
Group
Waveform Transfer
Syntax
WFMOutpre:SPAN?
Examples
RF:SPAN? might return 10.0000E+6, indicating the span is 10MHz.
WFMOutpre:WFId? (Query Only)
This query returns a string that describes several aspects of the acquisition
parameters for the source waveform, including Source, Coupling, Vertical
Scale, Horizontal Scale, Record Length and Acquisition Mode. If the waveform
specified by DATa:SOUrce command is not turned on, an error will be generated.
(See page 2-95, Waveform Transfer Command Group.)
(See page D-1, Waveform Transfer (WFMOutpre and CURVe Query) Examples.)
Group
Waveform Transfer
Syntax
WFMOutpre:WFId?
Related Commands
DATa:SOUrce
Returns
<QString> comprises the following comma-separated fields documented in
the tables below:
2-968 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO3000 Series and is the answer not in the manual?

Tektronix MDO3000 Series Specifications

General IconGeneral
BrandTektronix
ModelMDO3000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals