Reference menu
The Reference menu can turn on or turn off reference memory waveforms from
the display. The waveforms are stored in the non-volatile memory of the
oscilloscope, and have the following designations: RefA and RefB.
To display (recall) or hide a reference waveform, follow these steps:
1. Push the Ref front panel button.
2. Push the side-menu button corresponding to the reference waveform you
wish to display or hide.
Reference waveforms have the following characteristics:
■
Reference waveforms are displayed in white
■
Two reference waveforms can be displayed at the same time
■
Vertical and horizontal scale readouts display at the bottom of the screen
■
Reference waveforms cannot be zoomed or panned
You can display one or two reference waveforms at the same time as "live"
channel waveforms. If you display two reference waveforms, you must hide one
waveform before you can display a different one.
Refer to Save Waveform for information on how to save reference waveforms.
See Save waveform on page 98.
Save-Recall
Push the Save/Recall button to save oscilloscope setups, screen images, or
waveforms, or to recall oscilloscope setups or waveforms.
The Save/Recall menu is made up of many submenus which you can access
through an Action option. Each Action option displays a menu that allows you to
further define the save or recall function.
Action options Comments
Save All Contains the option that configures the Print button to send data to a
printer or to save data to a USB flash drive
Save Image Saves a screen image to a file in a specified format
Save Setup Saves the current oscilloscope settings to a file in a specified folder or in
nonvolatile setup memory
Save Waveform Saves the specified waveform to a file or to reference memory
Recall Setup Recalls an oscilloscope setup file from a USB flash drive or from a
location in nonvolatile setup memory
Recall Waveform Recalls a waveform file from a USB flash drive to reference memory
Reference