Set Maximum Backup ET
1. Within the Setup menu, turn the Upper Line knob to view the
following display:
Turn the Lower Line knob to adjust the decimal number value.
MAX BACKUP ET Part 1
2.00
The Maximum Backup ET value is a failsafe measure used by the
controller to calculate daily watering requirments in the event that
current ET Everywhere data is not recieved for an extended period.
2.
The Maximum Backup ET default value of 2.00 is automatically
entered to help compensate for seasonal weather changes.
The whole number of the Maximum Backup ET value is selected
by default. To adjust the value from 1 – 3, turn the Lower Line
knob.
Note: The Maximum Backup ET is adjustable from 0.50 – 3.99.
The whole number is only adjustable to 0 when the decimal
number value is .50 or higher.
4.
Turn the Upper Line knob right one stop to select the decimal
number.
3.
15
The controller features a Valve Test feature that will test each station
for a short-circuit condition each time it is activated. If a fault is detected,
an Alert will be posted, enabling identification and repairs to be made.
1. Within the Setup menu, turn the Upper Line knob to view the
following display:
2. Turn the Lower Line knob to select Yes or No as preferred.
RUNTIME VALVE TEST
No (Check Fuse Often)
Set Runtime Valve Test Option