2060, 2860/70 ADJUSTMENT 1 - 10 Dec. 1996 © TOSHIBA CORP.
1.2.3 Adjustment mode (05)
In this mode, the following adjustment items can be corrected or changed (see the Adjustment Code
List for “05” Mode). To access this code, turn on the power while pressing the “0” and “5” keys.
Adjustment item Code Key to adjust with Key to store with Remarks
Auto-toner sensor 0 Zoom keys INTERRUPT See 1.3 for details.
Exposure 1–17 Zoom keys INTERRUPT See 1.4 for details.
Automatic adjustment 49 Not needed Not needed
for exposure
HVT output 38–40 Zoom keys INTERRUPT See 1.6 for details.
Registration 53–59 Digital keys INTERRUPT See 1.5 for details.
ADF EEPROM initialization and
97 Not needed Not needed
automatic adjustment for ADF sensor
Other adjustment Except for Digital keys INTERRUPT Refer to Adjustment
above codes code list.
<Procedure>
*2
*3
*4
0 5
49
0 9
Automatic adjustment
PRINT
PWR
(Possible only after automatic
adjustment is finished)
** Duplex copying is not available using E/S key in the adjustment mode.
PWR
0 5
00 9
PWR
PRINT
Automatic adjustment for Auto-toner
INT
Memory set
Exit
PRINT
ADF sensor automatic adjustment
ADF EEPROM initialization
0 5
97
0 9
Finish 2
sec. later
Exit
*4
*3
*2
ADJUST
PWR
Code
PRINT E/S
Exit
**Test copy
0 5
0 9
Memory set
INT
Exit