EasyManuals Logo

Toshiba RAV-GM1101ATP-E User Manual

Toshiba RAV-GM1101ATP-E
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
No.
6
Part name
Compressor
Compressor lead
(Continued)
Procedure
2. Mounting of compressor
1) Mount the compressor in the reverse
procedure of removal.
NOTES:
After exchange of the compressor, be sure to
exchange the compressor lead. (Repair part
code of compressor lead: 43T60443)
Remarks
Header pipe
Soundproof
plate (upper)
Do not make
clearance
between the
soundproof
plate (upper)
and the
soundproof
plate (outer
winding).
Soundproof plate
(outer winding)
Accumulator
Discharge
pipe
Pass the soundproof
plate (inner winding)
through between
compressor and
discharge pipe, suction
pipe and then put it on
the other side at this
position.
Pass the soundproof
plate (outer winding)
through between the
suction pipe and
accumulator and
then put it on the
other side at this
position.
Pipe cover, bundling
band, each sensor
(TL, TO, TE, TD, TS
sensors) PMV coil lead.
Pipe cover, bundling
band, each sensor
(TL, TO, TE, TD
sensors) PMV coil
lead.
Bundling band, each
sensor (TL, TO, TE
sensors)
Suction pipe
PMV coil lead
Fix the removed each sensor and PMV coil
lead wire to the discharge pipe and the
suction pipe with the bundling band via the
pipe cover.
In this time, take note that each sensor and
PMV coil lead wire do not come to contact
with the discharge pipe and the reactor.
(For fixing to the discharge pipe, use the
black heat-proof pipe cover and the bundling
band for heat-proof which is sold on the
market.)
As shown in the right figure, mount the
soundproof plate (inner winding, outer
winding) by inserting between the compres-
sor and the piping, and between piping and
the partition plate.
Put the compressor lead wire and the
compressor case thermo between inner
winding and outer winding of the soundproof
as if dropping them in.
Suction pipe
- 111 -
FILE NO. SVM-18043

Table of Contents

Other manuals for Toshiba RAV-GM1101ATP-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAV-GM1101ATP-E and is the answer not in the manual?

Toshiba RAV-GM1101ATP-E Specifications

General IconGeneral
BrandToshiba
ModelRAV-GM1101ATP-E
CategoryAir Conditioner
LanguageEnglish

Related product manuals