Model Number Descriptions
Unit Model Number
Digit 1, 2, 3, 4 Unit Model
ACRA = Air-Cooled Screw Chiller
Digit 5, 6, 7 Nominal Tonnage
150 = 150 Tons
165 = 165 Tons
180 = 180 Tons
200 = 200 Tons
225 = 225 Tons
250 = 250 Tons
275 = 275 Tons
300 = 300 Tons
Digit 8 Unit Voltage
A = 200/60/3
B = 230/50/3
C = 380/50/3
D = 380/60/3
E = 400/50/3
F = 460/60/3
G = 575/60/3
H = 400/60/3
Digit 9 Manufacturing Location
U = Trane Commercial Systems, Pueblo, CO
USA
Digits 10, 11 Design Sequence
** = Factory assigned
Digit 12 Unit Sound Package
1 = InvisiSound Standard Unit
2 = InvisiSound Superior (Line Wraps,
Reduced Fan Speed)
3 = InvisiSound Ultimate (Compressor
Sound Attenuation, Line Wraps, Reduced Fan
Speed)
Digit 13 Agency Listing
0 = No Agency Listing
A = UL/cUL Listing
Digit 14 Pressure Vessel Code
A = ASME Pressure Vessel Code
C = CRN or Canadian Equivalent Pressure
Vessel Code
D = Australia Pressure Vessel Code
Digit 15 Factory Charge
1 = Refrigerant Charge R-134a
2 = Nitrogen Charge
Digit 16 Evaporator Application
F = Standard Cooling (40 to 65°F/5.5 to 18°
C)
G = Low Temp Process Cooling (below 40°F/
5.5°C)
C = Ice Making (20 to 6°F/7 to 18°C) with
Hardwired Interface
Digit 17 Evaporator Configuration
N = 2-pass Evaporator
P = 3-pass Evaporator
Digit 18 Evaporator Fluid Type
1 = Water
2 = Calcium Chloride
3 = Ethylene Glycol
4 = Propylene Glycol
5 = Methanol
Digit 19 Water Connection
X = Grooved Pipe
F = Grooved Pipe + Flange
Digit 20 Flow Switch
1 = Factory Installed - Other Fluid (15 cm/s)
2 = Factory Installed - Water 2 (35 cm/s)
3 = Factory Installed - Water 3 (45 cm/s)
Digit 21 Insulation
A = Factory Insulation All Cold Parts 0.75”
B = Evaporator-only Insulation for High
Humidity/Low Evap Temp 1.25”
Digit 22 Unit Application
1 = Standard Ambient (32 to 105°F/0 to
40.6°C)
2 = Low Ambient (0 to 105°F/-17.7 to 40.6°
C)
3 = Extreme Low Ambient (–20 to 105°F/
-28.9 to 40.6°C)
4 = High Ambient (32 to 125°F/0 to 52°C)
5 = Wide Ambient (0 to 125°F/-17.7 to 52°C)
Digit 23 Condenser Fin Options
A = Aluminum Fins with Slits
D = CompleteCoat Epoxy Coated Fins
Digit 24, 25 Not Used
00 = Reserved for future use
Digit 26 Power Line Connection
Type
A = Terminal Block
C = Circuit Breaker
D = Circuit Breaker with High Fault Rated
Control Panel
Digit 27 Short Circuit Current
Rating
A = Default A Short Circuit Rating
B = High A Short Circuit Rating
Digit 28 Transformer
0 = No Transformer
1 = Factory Installed Transformer
Digit 29 Line Voltage Harmonic
Mitigation
X = DC Reactors (~30% TDD)
1 = Filter circuit (IEEE519 Compliant)
Digit 30 Electrical Accessories
0 = No Convenience Outlet
C = 15A 115V Convenience Outlet (Type B)
Digit 31 Remote Communication
Option
0 = None
1 = LonTalk® Interface (LCI-C)
2 = BACnet® MS/TP Interface
3 = Modbus Interface
Digit 32 Hard Wire Communication
X = None
A = Hard Wired Bundle - All
B = Remote Leaving Water Temp Setpoint
C = Remote Leaving Temp and Demand Limit
Setpoints
D = Programmable Relay
E = Programmable Relay and Leaving Water
and Demand Limit Setpoint
F = Percent Capacity
G = Percent Capacity and Leaving Water and
Demand Limit Setpoint
H = Percent Capacity and Programmable
Relay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Ascend ACR Series and is the answer not in the manual?

Trane Ascend ACR Series Specifications

General IconGeneral
BrandTrane
ModelAscend ACR Series
CategoryChiller
LanguageEnglish

Related product manuals