EasyManuals Logo
Home>TSI Instruments>Measuring Instruments>Aerotrak 9303

TSI Instruments Aerotrak 9303 Service Manual

TSI Instruments Aerotrak 9303
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
v
Warranty
Part Number
6007706 / Revision F / August 2022
Copyright
©TSI Incorporated / 2014-2022 / All rights reserved.
Address
TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA
E-mail Address
answers@tsi.com
Limitation of Warranty and
Liability (effective February 2015)
(For country-specific terms and conditions outside of the USA, please visit www.tsi.com.)
Seller warrants the goods, excluding software, sold hereunder, under normal use and service
as described in the operator's manual, to be free from defects in workmanship and material for
12 months, or if less, the length of time specified in the operator's manual, from the date of
shipment to the customer. This warranty period is inclusive of any statutory warranty. This
limited warranty is subject to the following exclusions and exceptions:
a. Hot-wire or hot-film sensors used with research anemometers, and certain other
components when indicated in specifications, are warranted for 90 days from the date of
shipment;
b. Pumps are warranted for hours of operation as set forth in product or operator’s manuals;
c. Parts repaired or replaced as a result of repair services are warranted to be free from
defects in workmanship and material, under normal use, for 90 days from the date of
shipment;
d. Seller does not provide any warranty on finished goods manufactured by others or on any
fuses, batteries or other consumable materials. Only the original manufacturer's warranty
applies;
e. This warranty does not cover calibration requirements, and seller warrants only that the
instrument or product is properly calibrated at the time of its manufacture. Instruments
returned for calibration are not covered by this warranty;
f. This warranty is VOID if the instrument is opened by anyone other than a factory
authorized service center with the one exception where requirements set forth in the
manual allow an operator to replace consumables or perform recommended cleaning;
g. This warranty is VOID if the product has been misused, neglected, subjected to accidental
or intentional damage, or is not properly installed, maintained, or cleaned according to the
requirements of the manual. Unless specifically authorized in a separate writing by Seller,
Seller makes no warranty with respect to, and shall have no liability in connection with,
goods which are incorporated into other products or equipment, or which are modified by
any person other than Seller.
The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated
herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR
PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER’S BREACH
OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED
TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY
OR INDUCED INFRINGEMENTS. BUYER’S EXCLUSIVE REMEDY SHALL BE THE
RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND
TEAR OR AT SELLER’S OPTION REPLACEMENT OF THE GOODS WITH NON-
INFRINGING GOODS.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR
BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES,
OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON
CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE
RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR,
AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN THE
CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE
OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE.
IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS, BUSINESS
INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL
DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING
OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be
brought against Seller more than 12 months after a cause of action has accrued. The goods

Table of Contents

Other manuals for TSI Instruments Aerotrak 9303

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSI Instruments Aerotrak 9303 and is the answer not in the manual?

TSI Instruments Aerotrak 9303 Specifications

General IconGeneral
Size Range .0.3 to 25 µm
Channel Sizes .0.3 µm and 5.0 µm fixed; 0.5, 1.0, 2.0, or 2.5 µm selectable middle channel.
Counting Efficiency .50% at 0.3 µm; 100% for particles > 0.45 µm (per ISO 21501-4 and JIS)
Concentration Limits .2, 000, 000 particles/ft3 at 5% coincidence loss
Zero Count Level .<1 count / 5 minutes (per ISO 21501-4 and JIS B9921)
Flow Rate .0.1 CFM (2.83 L/min)
Calibration .NIST traceable with TSI® calibration system
Sampling Modes .Manual and automatic
Sampling Time .1 second to 99 minutes 59 seconds
Sampling Frequency .1 to 999 cycles or continuous
Light Source .Long life laser diode
Sample Probe/Tubing .Isokinetic sampling probe
Exhaust .Internal HEPA filter
Vacuum Source .Internal pump
External Surface .High impact injection molded plastic
Communication Mode .USB serial output
Data Storage .1, 500 sample records
Status Indicators .Low battery and service
Display .3.2-in. (8.1 cm) 160 x 160 monochrome LCD
AC Power . (power to AC adapter)110 to 240 VAC 50-60 Hz Universal in-line power supply with country specific plugs
DC Power . (power to instrument)9 VDC @ 1.5 A
Battery .Rechargeable Li-Ion
Battery Life .Up to 4.5 hours of continuous use
Recharge Time .< 3 hours
Weight and Dimensions IconWeight and Dimensions
Dimensions (L x W x H)9.1 x 6.3 x 2.4 in. (23 x 11 x 6.2 cm) (without isokinetic inlet)
Weight .1.3 lbs (0.58 kg) with battery