1.10.2 Digital audio interface
SARA-G340, SARA-G350 and SARA-U2 modules provide one 1.8 V bidirectional 4-wire (I2S_TXD data output,
I2S_RXD data input, I2S_CLK clock, I2S_WA world alignment) I
2
S digital audio interface that can be used for
digital audio communication with external digital audio devices as an audio codec.
The I
2
S interface can be set to two modes, by the <I2S_mode> parameter of the AT+UI2S command:
PCM mode
Normal I
2
S mode
The I
2
S interface can be set to two configurations, by the <I2S_Master_Slave> parameter of AT+UI2S:
Master mode
Slave mode
SARA-G340 and SARA-G350 modules do not support I
2
S slave mode: module acts as master only.
The sample rate of transmitted/received words can be set, by the <I2S_sample_rate> parameter of AT+UI2S, to:
8 kHz
11.025 kHz
12 kHz
16 kHz
22.05 kHz
24 kHz
32 kHz
44.1 kHz
48 kHz
SARA-G340 and SARA-G350 modules do not support the <I2S_sample_rate> parameter of AT+UI2S: the
sample rate is fixed at 8 kHz only.
The <main_uplink> and <main_downlink> parameters of the AT+USPM command must be properly configured
to select the I
2
S digital audio interfaces paths (for more details, see the u-blox AT Commands Manual [3]):
<main_uplink> must be properly set to select:
o the I
2
S interface (using I2S_RXD module input)
<main_downlink> must be properly set to select:
o the I
2
S interface (using I2S_TXD module output)
Parameters of digital path can be configured and saved as described in the u-blox AT Commands Manual [3],
+USGC, +UMGC, +USTN AT commands. Analog gain parameters are not used when digital path is selected.
The I
2
S receive data input and the I
2
S transmit data output signals are respectively connected in parallel to the
analog microphone input and speaker output signals, so resources available for analog path can be shared:
Digital filters and digital gains are available in both uplink and downlink direction
Ringer tone and service tone are mixed on the TX path when active (downlink)
The HF algorithm acts on the I
2
S path
See the u-blox AT Commands Manual [3]: AT+UI2S command for possible settings of the I
2
S interface.
I
2
S pins of SARA-G3 modules product versions “02” onwards can be used additionally for diagnostics.