EasyManuals Logo
Home>Ublox>Control Unit>SARA-R422

Ublox SARA-R422 User Manual

Ublox SARA-R422
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
SARA-R4 series - System integration manual
UBX-16029218 - R20 Design-in Page 58 of 128
C1-Public
2.2.1.12 Guidelines for grounding layout design
Good connection of the module GND pins with application board solid ground layer is required for
correct RF performance. It significantly reduces EMC issues and provides a thermal heat sink for the
module.
Connect each GND pin with application board solid GND layer. It is strongly recommended that
each GND pad surrounding VCC pins have one or more dedicated via down to the application board
solid ground layer
The VCC supply current flows back to main DC source through GND as ground current: provide
adequate return path with suitable uninterrupted ground plane to main DC source
It is recommended to implement one layer of the application board as ground plane as wide as
possible
If the application board is a multilayer PCB, then all the board layers should be filled with GND plane
as much as possible and each GND area should be connected together with complete via stack
down to the main ground layer of the board. Use as many vias as possible to connect the ground
planes
Provide a dense line of vias at the edges of each ground area, in particular along RF and high speed
lines
If the whole application device is composed by more than one PCB, then it is required to provide a
good and solid ground connection between the GND areas of all the different PCBs
Good grounding of GND pads also ensures thermal heat sink. This is critical during connection,
when the real network commands the module to transmit at maximum power: correct grounding
helps prevent module overheating.
2.2.2 Generic digital interfaces supply output (V_INT)
2.2.2.1 Guidelines for V_INT circuit design
SARA-R4 series modules provide the V_INT generic digital interfaces 1.8 V supply output, which can
be mainly used to:
Indicate when the module is switched on and it is not in the deep sleep power saving mode (as
described in sections 1.6.1, 1.6.2)
Pull-up SIM detection signal (see section 2.5 for more details)
Supply voltage translators to connect 1.8 V module generic digital interfaces to 3.0 V devices (e.g.
see 2.6.1)
Enable external voltage regulators providing supply for external devices
Do not apply loads which might exceed the maximum available current from V_INT supply (see
SARA-R4 series data sheet [1]) as this can cause malfunctions in internal circuitry.
V_INT can only be used as an output: do not connect any external supply source on V_INT.
ESD sensitivity rating of the V_INT supply pin is 1 kV (HBM according to JESD22-A114). Higher
protection level could be required if the line is externally accessible and it can be achieved by
mounting an ESD protection (e.g. EPCOS CA05P4S14THSG) close to accessible point.
It is recommended to monitor the V_INT pin to sense the end of the internal switch-off sequence
of SARA-R4 series modules: VCC supply can be removed only after V_INT goes low.
It is highly recommended to provide direct access to the V_INT pin on the application board by
means of an accessible test point directly connected to the V_INT pin, for firmware upgrade and/or
for diagnostic purposes.

Table of Contents

Other manuals for Ublox SARA-R422

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R422 and is the answer not in the manual?

Ublox SARA-R422 Specifications

General IconGeneral
BrandUblox
ModelSARA-R422
CategoryControl Unit
LanguageEnglish

Related product manuals