22
To measure current, connect the Meter as follows:
1.
2.
Model UT805: OPERATING MANUAL
COM
RL
DCI
COM
RL
ACI
C. DC or AC Current Measurement (see figure 6)
Warning
If the fuse burns out during measurement, the Meter
may be damaged or the operator himself may be hurt.
Use proper terminals, function, and range for the
measurement. When the testing leads are connected
to the current terminals, do not parallel them across
any circuit.
ACI or DCI measurement do not have auto ranging
measurement mode.
Press ACI or DCI button only to select 10A
measurement range. Insert the red test lead into
the 10A MAX terminal and black test lead into the
COM terminal. OR
Press ACI or DCI button, then press 2mA button to
select 2mA measurement range. Insert the red test
lead into the 200mA MAX terminal and black test lead
into the COM terminal. OR
(figure 6)