1.
2.
Model UT805: OPERATING MANUAL
B. Replacing the Fuses (see figure 13)
Warning
To avoid electrical shock or arc blast, or personal
injury or damage to the Meter, use specified fuses
ONLY in accordance with the following procedure.
To replace the Meter’s fuse:
Turn the Meter off, disconnect the power cord and
remove all connections from the terminals.
Fuse 1:The line power fuse is in series with the power
supplier. This fuse is located at the top of the power
-line cord connector on the rear panel.
To replace this fuse, unplug the line cord and remove
the line power fuse housing to install the replacement
fuse.
Fuse 2 and 3:These two fuses are located inside the
fuse compartment. To replace these fuses, first
unplug the line cord. Then use a coin to open the
accessories compartment at the top of the front cover,
then you will see a fuse compartment. Open the fuse
compartment to replace fuse 2 and 3. Remove the
fuse by gently prying one end loose, then take out
(figure 13)