SLOWTOP
YES
Replace the core
probe
NO
YES
Replace the core
probe
NO
Replace the power
board
WM03 core
probe
warning
Turn off the power
supply and disconnect the
P23 socket. Measure
the
impedance of the
probe
setting the
multimeter to ohm.
You should find 110 ohm
at about 25 °C (77 °F)
Do you measure
between the white
cables a value of
110 ohm at about
25 °C (77 °F)?
Do you have
between the white
cables an infinite value
(OL on the instrument
display)?