10.8 DESCRIPTION OF THE
SETTABLE FUNCTIONS
t 01&3"5*/(.0%&
It permits to modify the central unit opera-
tion by adapting it to the mode with or with-
out T3 technology.
t MACHINE UNITS
It permits to select the delivery unit number
that are actually present on the machine.
t LEFT AUTOSTEAM
It permits to enable/disable the left
autosteam/Easycream.
t RIGHT AUTOSTEAM
It permits to enable/disable the right
autosteam/Easycream.
t AUTO-LEVEL WITH PUMP
It permits to enable/disable the pump during
the auto-level.
t HOT WATER WITH PUMP
It permits to enable/disable the pump during
hot water delivery.
t LEVEL SENSITIVITY
It permits to set 3 different sensitivity levels
for auto-level.
1 330 kOhm - normal water.
2 470 kOhm - water with a low presence of
minerals.
3 600 kOhm - water with a very low level of
minerals.
When the machine should be filled but it is
not, the probe may not detect the presence
of water. This option is considered only in
extreme cases.
t DELIVERY LEVEL
It permits to enable/disable the autosteam
even during a delivery.
t CALIB. OF STEAM PROBE 1
It permits to calibrate the steam probe 1.
The values shown are expressed in °C or
°F according to the unit of measure set for
the machine. In case of °C, the increase/
decrease is of one unit at a time, while in
case of °F the increase/decrease may also
be of 2 units at a time.
Edition 01 of 08/2017
10.8
SERVICE MANUAL
Menu PrincipaleTechnical settings
Preinfusion
Serial connection
Fig. 360