Edition 01 of 08/2017
6.13
SERVICE MANUAL
Fig. 178
OFF
Fig. 179
OFF
CLOCK DISABLED
Fig. 180
6.8 PROCEDURE
FOR AUTOMATICALLY FILL-
ING THE COFFEE BOILER
Once the various parts of heater, or the heater
itself, have been replaced it is necessary to care-
fully fill it to prevent it from starting to heat in the
absence of water.
If this were to happen the thermal fuse would
break to protect the heating elements.
The steps are:
1 Re-open the water tap at the entrance to the
pump.
Turn on the machine by pressing the power but-
ton located on the side of the screen and place
it IMMEDIATELY in the condition in which the
screen displays the status “OFF”.
Press and hold the wash button until the screen
displays “CLOCK DISABLED”.
Now press the power button: in this way the
operational mode will be that entered before
installation which will properly fill all coffee boil-
ers for 45 seconds. Wait until the water is uni-
formly delivered by all units.