Draining:
1 Close the sea cock.
2 Connect a hose to each drain tap before opening
the tap (one at a time).
3 Open the drain taps/remove the drain plugs (S) and
allow the water to run out.
Drain points:
- tap at rear of heat exchanger
- tap at rear of charge air cooler
- Open the drain taps/remove the drain plugs (S)
and allow the water to run out.
Check that all water really does drain out. Depos-
its may need to be cleared away, inside the drain
plug/tap.
4 Also drain/empty any auxiliary equipment such as
the seawater filter, flushing/bilge pump etc.
5 Install the lid on the flushing/bilge pump if fitted.
Connect all hoses.
6 Close/install all drain taps and plugs before you
leave the boat.
7 Check for leaks before you leave the boat.
Zinc Anodes, Check and Change
WARNING!
Risk of water entry. Close the seawater cocks before
doing any work on the seawater system.