EasyManuals Logo
Home>WAGNER>Control Unit>EPG-Sprint X

WAGNER EPG-Sprint X User Manual

WAGNER EPG-Sprint X
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
37
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
6.6 GROUNDING
For safety reasons the system must be properly grounded. WAGNER recommends the use
of a copper cable of at least 16 mm² with su cient mechanical resistance for connection
to the signal ground.
Good grounding of the work piece is also necessary for optimum powder coating.
A poorly grounded work piece causes:
dangerous electric charging of the work piece,
very poor wrap-around,
uneven coating,
back spraying to the gun, i.e., contamination
Prerequisites for perfect grounding and coating are:
Conducting suspension for the work piece that is to be coated.
Grounding of the powder coating booth, transport and suspension equipment to
be provided on site in accordance with the corresponding operating manuals or the
de nitions laid down by the manufacturer.
Regular cleaning of hangers from powder residues.
Grounding resistance for the work piece of a maximum of 1 MΩ (megaohm).
Grounding cable connected to the controller module or control cabinet.
Sparks between work piece and conveyor hooks (hangers) can occur if hooks or
other hanger parts are not completely cleaned! These sparks can cause heavy radio
frequency interference.
Perform safety checks in accordance with Chapter 8.2.3.
6.7 SAFETY CHECKS

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals