33
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2354920
SPRINT XE
Procedure:
1. Connect the hose (black) for mains pressure.
2. Plug in the control cable from the solenoid valve on the control unit.
3. Connect the dosing air hose (blue).
4. Connect the feed air hose (red).
5. Connect the uid air hose (black).
Bundle the three hoses with Velcro cable binders.
6. Connect the powder feed hose.
7. Plug in the gun connection cable on the control unit.
8. Connect the hose (transparent) for the atomizing or Tribo air.
Bundle the two hoses and the gun cable with Velcro cable binders.
9. Connect the compressed air hose (12.5x18.5 mm, Order No. 9981951) to the compressed
air connection (G1/4") on the manual system.
10. Connect the trolley grounding cable to the control unit.
Connect the control unit's grounding cable with the signal ground!
11. Plug in the connection cable from the vibrator motor on the control unit.
Fasten the connection cable to the trolley with the delivered Velcro cable binders
(Detail A).
12. Plug in the control unit mains cable.
13. Connect mains cable to the power supply.