41
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2354920
SPRINT XE
7.2.3 ADJUSTING FLUIDIZATION (60 L TANK WITHOUT VIBRATOR TABLE)
WARNING
Dust formation!
Risk of poisoning if inhaled.
Danger due to escaping dust, contamination of the device and device components.
The powder tank may only be lled to the halfway mark, because uidizing increases
the volume of powder.
P_02647
1
2
Procedure:
1. Open the lid and ll the powder tank (1) halfway
with powder.
2. Switch on the control unit.
3. Set the "Vibrator motor controller" parameter, on
the control unit, to "ON" to permanently activate
the uid air (see the EPG-Sprint XE control unit
operating manual).
4. Actuate the trigger of the spray gun for a short time
and release it.
5. Adjust the uid air at the throttle (2) until uidization
is recognizable.
Note:
– The amount of uid air depends on the
characteristics of the powder.
Avoid a build up of powder dust (too much uid
air) in the powder tank!
6. Close the powder tank 1 and check whether the
exhaust air hose is leading in the direction of the
ventilation system of the powder coating booth.
Note:
–
We recommend using a vibrator table when
working with powders that are di cult to feed
(see Chapter
12.13).