English | 3 | Machine description
14 | 89014383; Version 2 | Operating instructions UC-Serie
3.9 Technical data
Name Note Unit Value
UC-S UC-M UC-L UC-XL
Rack dimensions mm 400 x400 500 x 500 500 x 500 500 x 500
500 x 540
Tank capacity l 9.5 15.3
Noise emission Standard,
Cool
Energy
dB(A) 55
Excellence-i(Plus) 62.5
IP protection class Plastic rear panel IPX3 -
Stainless steel rear
panel
IPX5
Min. water flow pressure Standard,
Cool
kPa (bar) 100 (1.0)
Energy 150 (1.5)
Excellence-i(Plus) 140 (1.4)
Max. inlet pressure
(back pressure)
kPa (bar) 1000 (10.0)
Flow rate Standard,
Cool
Excellence-i(Plus)
l/min min. 4
Energy min. 3
Inlet water temperature Standard °C max. 60
Cool
Energy
max. 20
Excellence-i(Plus) max. 35
Exhaust air
Observe local guidelines, e.g. DIN EN 16282 / VDI guideline 2052 when constructing the ventilation system.
Operating conditions
Name Unit Value
Temperature at the installation site °C 0 - 40
Relative air humidity at the installation site % < 95
Storage temperature °C > -25
Max. height of the installation location above sea
level
m 3000