Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-163
FIP 1. 89
017-987 FAX Controller Error
Cause:
Cannot read file because it is bigger than read destination buffer.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Wait until the Pending FAX Jobs will be sent, or delete the Pending FAX data.
2. Divide the FAX data into smaller blocks or convert the data to a smaller format.
3. Update to the latest F/W.
4. Power the printer Off and On. If there is still an issue, replace the following parts in sequence.
•(REP 5.4 Fax PWB)
•(REP 5.1 ESS PWB)
FIP 1. 90
017-988 Scan Time Out
Cause:
Timeout at start of Scan To Application.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Check the USB connection.
2. Reconnect the PC and the printer.
3. Set these items correctly. (Scan Form/Image Type/Resolution/Paper size/Output Destination)
4. Ensure that the error is replicated after the printer is powered Off and then On, and then
Install the correct Driver Software.