45
DXS12/DXS15
2-18.
Residual noise level
Perform measurement with no signal input.
The noise level generated in the output terminal is
measured.
Confi rm that the output noise level is within the specifi ed
below.
SP OUT (LF)
CN609-1 (OUT+_L) :
-58 dBu or less
CN609-3 (OUT-_L) :
2-19.
Analog mute inspection
Execute A-MUTE inspection of diagnostic mode.
Set the level control (INPUT) to the maximum position.
The signal of -10 dBu is input to INPUT terminal (XLR) L.
A-MUTE is operated, and the output voltage is measured.
Confi rm that the output level is within the specifi ed below.
SP OUT (LF)
CN609-1 (OUT+_L) :
-10 dBu or less
CN609-3 (OUT-_L) :
2-20.
Confi rming the operation in AC 230 V
The AC power-supply voltage is adjusted to 230 V±10 %.
When the sine wave is input to INPUT terminal (XLR) L.
The following outputs are obtained, power consumption is
measured.
SP OUT (LF)
CN609-1 (OUT+_L) 29.2±0.1 dBu :
114 W±10 W
CN609-3 (OUT-_L) (62.5±1.5 W/8 Ω) :