This test specification is applied to the AMP assembly
12W/15W.
1. Measurement Conditions
1-1-1. Measuring Instrument and jigs
• Use a reliable measuring device capable of precisely
measuring the specification values indicated in this
document.
• Input impedance of the measuring instrument should
be more than 100 kΩ.
• Use the 22kHz low pass fi lter for the measurement of
the noise, total harmonic distortion, maximum output
and analog mute.
• Serial Communication Jig (WP327800) x 1
• DSR-CS Wiring Assembly (WW332900) x 1
• RS232C Cross Cable x 1
• DXR-JIG Wiring Assembly (ZC114300) x 1
(for board repair)
1-1-2. Measurement Filter
Use the following fi lters for the measurements in 2-12 to
2-20.
• THRU/SPOUT(LF)
: Audio Precision AUX-0025
* For (LF) measurement, it is best to connect
AUX-0025.
• In (LF) measurement, do not use a common ground
for the signal generator, AMP assembly, and
measuring instrument.
• Use a 22 kHz low-pass fi lter according to the
measurement item.