6D93G11
4-20
1
2
3
4
5
6
7
8
9
Checking the canister
1. Check the canister for cracks. Replace if
necessary.
2. Connect the special service tool to the
atmospheric port
1
and cover the other
ports, each with a finger.
3. Apply the specified positive pressure and
check that there is no air leakage.
Replace the canister if there is air leak-
age.
Vacuum/pressure pump gauge set:
90890-06756
Specified pressure:
19.6 kPa (0.196 kgf/cm
2
, 2.8 psi)
S6D84160
1
Canister