Electronic Commercial Water Meter
AquaMaster™ 4 Start-Up And Operation
IM/AM Issue 13 35
4.3 Display Activation
For normal operation, activate the light sensitive display by first covering the display area totally.
On removing the covering, the display activates and cycles through the programmed set of display
measurements.
Fig. 4.2 Location of Controls
Note. For the use of local or remote serial communication and how to alter the displayed set of
measurements, or instrument setup, see the Quick Reference Programming Guide.
Lower Display
Time
Flow Velocity
Pressure
Left Battery Warning
Sensor Fault
Empty Pipe condition
Mains Failure
Right Battery Warning
Upper Display
Date
Forward Flow Total
Reverse Flow Total
Net Flow Total
Pictorial Displays
Warning annunciators
8gal
m
3
AB
CD
ftm
3
/hMGD
gal/sm Barpsi
0
-
88888.888.
.8.8.8.80