Note: The Safe motor temperature function is motor-specific. This is
the case also in ACS880 multidrives where multiple motors are
connected to the drive.
Drives and modules
The module is available as a factory-installed option (+L537+Q971)
or as an add-on kit for ACS880 drives and modules.
To install the kit, the user:
makes sure that the serial number of the drive/inverter module
starts with 1, 4, 7, 8, M or Y
attaches the included ATEX label for the SMT function to the
drive/inverter module to ensure the ATEX compliance of the
safety circuit
installs the option module to an option slot of the drive control
unit and sets the applicable drive parameters
connects the PTC temperature sensors of the motor to the PTC
inputs of the option module
connects the drive STO terminals to the STO output of the option
module (or to the FSO module and then configures the FSO
module to do the STO function).
Cabinet-built drives
For cabinet-built ACS880 single drives and ACS880 multidrives, the
module is available as factory-installed options:
+L537+Q971
+L537+Q971+Q973 (with the FSO-12 module)
+L537+Q971+Q972 (with the FSO-21 module)
+L537+Q971+Q972+L521 (with the FSO-21 and FSE-31
modules).
The user connects the PTC temperature sensors of the motor to the
PTC inputs of the module.
30 Option description and instructions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB FPTC-02 and is the answer not in the manual?

ABB FPTC-02 Specifications

General IconGeneral
BrandABB
ModelFPTC-02
CategoryControl Unit
LanguageEnglish

Related product manuals