000704AG
9 - Attachments
9
Attachments
Port and network services used by the inverter
IP Network Services
Any network connected to the inverter must allow trafc to pass on the
following ports. Network rewall rules (if present) must allow responses
to the inverter over existing TCP connections.
Direction Service/Port Protocol Description
Out ssh/22 Tc p
For remote debugging by ABB service personnel, the inver-
ter utilizes encrypted SSH Remote Login Protocol. To allow
service personnel remote access to the inverter, this port
has to be opened in any rewall and forwarded to the inver-
ter. (preferred)
Out domain/53 Tcp/udp
The inverter must be able to resolve domain names, to en-
sure scalability and dynamic changes on the Internet (DNS).
(required)
Out https/443 Tc p
As an HTTP client, the inverter uses SSL/TLS protocol con-
nections to Aurora Vision
®
servers for secure communica-
tion. The inverter uses this port for all services, including
data transmission, rmware upgrade, conguration mana-
gement, and remote command transmission. (required)
Out
dhcp/67,
dhcp/68
Udp
If DHCP service is not available, static network information
must be assigned to the inverter (preferred)
Out ntp/123 Udp
The inverter uses this port for network time services (NTP).
(preferred)