Test Development
i3070 Series 5i Help 3-9
Top Fixture Height After Compression
The overall height from the top plate to the bottom of the PCB must be
184.6 mm (7.27 in) after compression, regardless of the PCB thickness.
Figure 3-8 Top Fixture: Front View After Compression
2YHUDOOKHLJKWIURP7RS3ODWH
WRERWWRPRI3&%PXVWEH
PPLQ
DIWHUFRPSUHVVLRQ
PP
PP
PP
3&%WKLFNQHVVPP 3&%WKLFNQHVVPP
PP
PP
7RS3ODWH
3UREH3ODWH
7RS)ORDWLQJ3ODWH
PP
Diagrams are not to scale