Page #29 background imageLoading...
Page #29 background image
Test Development
i3070 Series 5i Help 3-3
Fixturing Guidelines
Board Placement and Specifications
Bottom Fixture
Top Fixture
Guide Pin
Top Fixture Height After Compression
ID Block
Optional Signals
Board Placement and Specifications
The Board Placement task decides the placement of the board on the
fixture and creates the fixture files. The placement of the board is
specified as X and Y offsets from the fixture origin to the board origin
and a rotation angle.
The default placement of the board is at the center of the modules with
the edge of the board 28.1 mm from the front edge of the fixture. The
keepout area is necessary to avoid blocked resources.
Figure 3-1 Board Placement
28.1 mm
(
± 0.1 mm)