Subsystem Command Reference 6
N9310A User’s Guide 125
FM Subsystem
The FM subsystem controls the settings and parameters
associated with frequency modulated signal.
FM State
:FM:STATe ON|OFF|1|0
:FM:STATe?
This command toggles the FM state between ON and OFF.
However, applying a frequency modulation to the RF carrier
requires you also set MOD on.
See “Modulation State Subsystem on page 137
The query returns the current FM state.
Range ON(1), OFF(0)
*RST value OFF
Returned data 1, 0
Front panel access FM > FM On/Off