Rockwell Automation Publication 1734-UM013N-EN-P - September 2017 147
Configuring Safety Connections between a GuardLogix Controller and POINT Guard I/O Modules on a DeviceNet Network Chapter 7
Review the Safety Device Verification Reports
The Review page displays safety devices with status of either Verify FAILED or
Ready to be Safety Locked.
1. Click Review in the Report column to launch the HTML report of the
device in your default browser.
2. To generate an HTML verification report for all devices listed, click
Review All.
3. Review and print the verification reports for your records.
Lock Safety Devices
If the status of a device is Verify FAILED, more information is provided
in the verification failure report.
You must review the device configurations and record the configuration
signatures before operating a safety application.
Before you lock your safety device configurations, you must perform all
verification steps that are required for your application.